Although the code does not specifically state that a washing machine receptacle has to be gfci the washing machine must have water service and a drain so its location becomes defined as a laundry.
Gfci required in laundry room.
For receptacles that are not readily accessible and for receptacles dedicated for a specific appliance that is not easily moved.
The requirement for afci protection in kitchens and laundry areas as well as for branch circuit extensions or.
If the water supply is permanently connected to washing machines in a laundry area does it require a class a gfci protected receptacle.
Gfci stands for ground fault circuit interrupter.
2005 does require gfci 6 from laundry sinks.
The requirement for gfci protection in laundry areas was deleted.
Gfci receptacles are required in bathrooms garages crawl spaces basements laundry rooms and areas where a water source is present.
If the laundry room does not have a window then an exhaust fan will be required along with a switch.
See the nec code requirements in the table below for more specific information.
210 8 a 10 all 125v 15a and 20a receptacles installed in laundry areas shall have gfci protection.
All receptacles must be gfci protected.
The only wiggle room for the washing machine is if it drains into a standpipe drain and there is no sink.
Occupancy controlled lighting will be required too.
Gfci protection is required for 125 volt to 250 volt receptacles supplied by single phase branch circuits rated 150 volts or less to the ground.
Where gfci protectio n is required.
A laundry room needs at least one 20 amp circuit for receptacles serving laundry equipment.
Otherwise you probably need a a new washing machine or you will be fixing you old one so it runs on a gfci.
Yes as of the 2017 edition of the national electrical code nec any receptacles in a laundry room must be gfci protected.
An electric dryer needs its own 30 amp 240 volt circuit wired with four conductors older circuits often have three conductors.
According to the nec a gfci is required if the power outlet is within 1 8 meter radius from the water source.
Now let s refer to nec 2017 section 210 8 for the answer to the gfci portion of our question.
The code mandate was later expanded to include any receptacles in a laundry room in the 2014 nec.
It s a device that protects people from receiving shocks from faults in an electrical system.
Gfci receptacles monitor any electric current imbalance between the circuit s hot and neutral conductor and shuts of the circuit if an imbalance is present.
Receptacles within 6 feet of a laundry sink were first required to be gfci protected by the 2005 edition of the national electrical code nec.
The nec doesn t require gfci protection for clothes washing machines specifically but it does for laundry areas.