If your refrigerator isn t cooling and you don t hear the fridge fan running this video guides you through diagnosing what s wrong with the refrigerator evaporator fan.
Ge evaporator fan not running.
Testing for this fan is done on the same pins but the voltage will be different.
See how to use continuity checks to identify the problem and make sure that the fan motor electronic control board and the wiring that connects them are work correctly.
To determine if the evaporator fan motor is defective try turning the fan blade by hand.
In many cases the problem is do to the fact that the evaporator fan cannot operate freely due to an ice.
The refrigerator may have one or more evaporator fan motor s depending on the model and evaporator locations.
The evaporator fan motor circulates the cold air from the coils thru the compartment.
I checked the voltage on pins 3 4 and it was 1 45 vdc.
Finally if the motor does not run at all use a multimeter to test the motor windings for continuity.
If you can hear the compressor running but the fridge isn t cooling the problem is most likely either frost clogged evaporator coils or a stuck or broken evaporator fan.
A stuck or broken evaporator fan usually makes chirping or squealing sounds.
Fresh food not cooling on ge dual evaporator refrigerators.
If the fan blade does not turn freely replace the fan motor.
The evaporator fan motor is an electronic component so you ll need to make sure there s no power running to it before you do any kind of work on it.
If you have a dual evaporator model and you need to check the fresh food evaporator fan please refer to this page.
If it doesn t the refrigerator won t get cool enough to preserve your food.
Here are some refrigerator troubleshooting tips to help you zero in on the problem if you notice your fridge not cooling.
Replace the refrigerator evaporator fan.
It s fairly easy to perform a continuity test on the fan to determine whether or not you need to replace it.
Ge refrigerator evaporator fan won t always run.
I checked the voltage from the control board to the evaporator fan motor pins 3 8 and got 14 52 vdc.
If there is only one evaporator it is in the freezer side.
The fan should come on whenever the compressor cycles on.
When this happens the fault could be in the wiring the control panel or the fan itself.
Follow the instructions below for testing this fan motor.
Compressor and condenser fan motor running evaporator fan not running.
In order to unplug the freezer you may need to slide it out away from the wall to gain access to the outlet behind it.
Additionally if the motor is unusually noisy replace it.
If the fan is not running unplug the refrigerator and remove the evaporator fan cover.